Slit Lamp Machine Price

Slit Lamp Machines Latest Price in India

Mediworks Digital Slit Lamp

Mediworks Digital Slit Lamp

The digital slit lamp is a commonly used device for eye examinations, enabling ophthalmologists to closely examine the front and interior of the eye. Designed to be simple, compact, and space-saving, it ensures easy operation. We are proud to be an importer, wholesaler, and supplier of the Mediworks S390L Slit Lamp in India.

Slit Lamp Mediworks S390L​

  • Meibomian glands photography&Auto AI analysis
  • Better optical performance
  • Built-in yellow filter
  • Simple capture every key moment
Microscope
Microscope TypeGalilean Type
Magnification ChangeRevolving Drum 5 steps
Total Magnification6.3X, 10X, 16X, 25X, 40X
Optical Resolution2700·N lp/mm (200 lp/mm)
Eyepieces12.5X
Angle between Eyepieces10°
Pupillary Adjustment52mm-80mm
Diopter Adjustment-8D~+8D
Field of ViewØ36.2mm, Ø22.3mm, Ø14mm, Ø8.9mm, Ø5.7mm

 

Slit Illumination
Slit Width0~14mm continuous (slit becomes a circle at 14mm)
Slit Length1~14mm continuous
Aperture DiametersØ14mm, Ø10mm, Ø5mm, Ø3mm, Ø2mm, Ø1mm, Ø0.2mm
Slit Angle0°~180°
Slit Inclination5°, 10°, 15°, 20°
FiltersHeat-absorbing filter, ND filter, Red-free filter, Cobalt Blue filter,Yellow filter built-in
LampLED
Luminance≥150klx

 

Power Supply
Input Voltage~100V-240V
Input Frequency50Hz/60Hz
Rated current1.2A
Output VoltageLED 3V, Fixation 15V
Packaging
Dimension740mm x 450mm x 530mm(L/W/H)
Gross weight23kg
Net weight17kg

 

System Specifications
Image Sensor5.0M Pixels
Photo Resolution2592 x 1944
FormatJPEG
Video Resolution2592 x 1944
Frame of Video25fps
Video FormatsMP4 H.264
Exposure ModeAutomatic exposure
Transmission InterfaceUSB

 

Computer Specifications
PC configurationi5-10500T 8G memory 25GB SSD+1TB storage
Display1920×1080 23.8inch
PC systemWindows 10

 

Rexxam Digital Photo Slit Lamp​

Rexxam Digital Photo Slit Lamp

RS-5000, RS-500

The new Rexxam RS series slit lamps feature high-quality optics, versatile functionality, and user-friendly design. The series includes three models: RS-5000, RS-500, and RS-300.

Significant improvements have been made to enhance smooth and comfortable operation, including a newly designed joystick and ergonomic base for precise and stable positioning.

The main and background illumination control dials are intuitively designed for easy one-handed use. A specially selected LED, closely matching the color temperature of traditional halogen lights, ensures optimal illumination.

For advanced digital imaging, the RS-5000 and RS-500 can seamlessly integrate with Rexxam’s optional DCS-700 digital camera, enabling outstanding image capture with a simple press of the joystick button.

RS-300

The RS-300 is the most cost-effective and practical option in the RS series. It features three-step magnification levels: 10x, 16x, and 25x with 13.5x eyepieces (or 13x, 21x, and 33x with optional 18x eyepieces). The optical system utilizes a Galileo-type design with parallel oculars. Its field of view ranges from 8–20mm, illuminated by an LED light source.

 

The RS-300 is a reliable, high-quality slit lamp ideal for primary operations in any practice.

RS-5000RS-500RS-300
MicroscopeTypeGalileo type
5 step drum rotation3 step drum rotation
Conversion12 degrees
Eyepieces12.5x13.5x (18x optional)
Magnifications (Field of View)6.4x (37mm)
10x(23mm)
16x(14.6mm)25x(9.5mm)
40x(5.9mm)
10x(20mm)
16x(13mm)
25x(8mm)

with18xoptionalEyepieces
13x(14mm)
21x(10mm)
33x(6mm)
Diopter Adjustment Range±7D±5D
Pupillary Distance52-80mm45-81mm
FilterYellow
Illumination SystemLight SourceLED
Slit Width0-15mm continuous
Slit Length0.5-15mm continuous
Slit Aperture Deameterφ0.2, φ1, φ3, φ5, φ8, φ15mm
Slit Tilt5, 10, 15, 20°
FiltersSelectableCobalt Blue, Heat absorption,
Green(Red free), ND
Cobalt Blue, Heat absorption,
Green(Red free)
Regular UseUV cut
Background IlluminationYesoptional
MovementUp-Down30mm
Right-Left100mm
Forward-Backward100mm
Fine Movementφ15mm(by Joystick)
Chin-rest Up-Down80mm
PowerPower VoltageAC 100-240V, 50/60Hz
Power Consumption70VA50VA
SizeWeight16.5kg15.0kg
Dimensions320mm(W)
450mm(D)
770mm(H)
320mm(W)
450mm(D)
590mm(H)
DCS-700 CompatibilityYesNo
Standard AccessoriesDust Cover, Chin-rest Paper, Test Bar, Diffuser, Base Plate
*RS-5000/RS-500 only

 

What is Slit Lamp Exam?

A slit lamp exam is a routine test that eye care professionals use to assess the overall health of your eyes. It allows them to examine all areas, including the internal structures, helping to diagnose problems or detect early signs of conditions such as glaucoma or cataracts.

What is a Slit Lamp?

A slit lamp is a specialised microscope with a bright light used in eye exams. It enables ophthalmologists to examine the front and interior structures of the eye in detail, helping to assess eye health and detect conditions early. The name “slit lamp” comes from the thin, adjustable beam of light it uses, which can be shaped into a slit. This focused beam makes it easier for eye care professionals to view different parts of the eye more clearly during the examination.

What is the Use of a Slit Lamp?​

A slit lamp is a specialised microscope with a bright light that is used during eye exams. It enables your ophthalmologist to closely view both the front structures and internal parts of the eye, making it easier to identify different eye conditions.

What is the Principle of a Slit Lamp?

A slit lamp is a stereoscopic biomicroscope that emits a concentrated beam of light, which can be adjusted in height, width, and angle. This sophisticated device provides a three-dimensional view and allows accurate assessment of the detailed anatomy of the adnexa and the eye’s anterior segment.

What is a Slit Lamp Exam?

  • A slit lamp exam is a common eye test that lets an eye care professional closely check all areas of your eyes, including internal structures. It is a key part of a routine eye exam.
  • The slit lamp itself is a specialised microscope with a bright, adjustable light. By changing the light’s focus, your eye care specialist can examine the layers of your eyes in detail, helping to assess overall eye health and detect any issues or symptoms.
  • Often, your pupils will be dilated for this test. Because dilation can temporarily blur vision and make driving unsafe, it’s best to arrange a ride or have someone accompany you to your appointment.

What Does This Exam Help Diagnose?

A slit lamp examination can help identify several eye conditions, such as:

  • Macular degeneration – A progressive disorder that affects the central part of vision.
  • Retinal detachment – When the retina, the light-sensitive layer at the back of the eye, separates from its supporting tissue.
  • Cataracts – Clouding of the lens that causes blurred or reduced vision.
  • Corneal injuries – Damage to the clear, outer layer of the eye.
  • Retinal vessel blockages – Blockages in the eye’s blood vessels, which can lead to sudden or gradual vision changes.

Be sure to discuss with your eye doctor what they are checking for and any conditions you might be at risk of developing.

What Happens During a Slit Lamp Exam?

  • When you sit in the exam chair, your doctor will place a device in front of you with supports for your chin and forehead to keep your head steady. They may use eye drops containing a yellow dye called fluorescein, which temporarily tints your tears to make any surface issues on your cornea easier to see. Additional drops may also be given to dilate your pupils, allowing a more detailed view of the inside of your eyes.
  • The examination is done using a slit lamp and a low-powered microscope. The slit lamp shines a bright, focused light and includes different filters to view various parts of the eye. Some clinics also use digital imaging tools to capture pictures, helping track any changes in your eyes over time.

When Would I Need a Slit Lamp Exam?

A slit lamp exam is usually recommended every few years to help your eye care professional track changes in your eyes and address any symptoms you may have. This test is an important screening tool for conditions such as:

 

  • Cataracts
  • Glaucoma
  • Dry eye
  • Corneal abrasions (scratches on the cornea)
  • Corneal disorders
  • Macular degeneration
  • Retinitis pigmentosa

 

Your eye care specialist will guide you on how often you should schedule this exam and explain which conditions or changes they are focusing on.

What Does a Slit Lamp Exam Show?​

There’s no special care needed after a slit lamp exam. However, if your pupils were dilated, avoid driving until they return to normal size.

 

While your pupils are dilated, your eyes may be more sensitive to light, so wearing sunglasses for a few hours can be helpful. Once the dilation wears off, you can resume your regular activities.

Reach Out